heil furnace codes

If you’re looking for help fixing your Heil furnace, look no further! Our comprehensive Heil furnace repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.

CODE: LED flashing like a heartbeat
PROBLEM: Control has 24 VAC power
FIX: n/a

CODE: Two LED flashes
PROBLEM: Unit’s pressure switch didn’t open
FIX: Check for an obstruction in the pressure tubing

CODE: Three LED flashes
PROBLEM: Unit’s pressure switch didn’t close or reopened
FIX: Check for: excessive wind; if it’s the proper vent size; defective inducer motor; defective pressure switch; inadequate combustion air supply; disconnected or obstructed pressure tubing; or restricted vent

CODE: Four LED flashes
PROBLEM: Limit circuit fault: either a limit or flame rollout is open
FIX: Check for: restricted vent; loose blower wheel; excessive wind; dirty air filter; or defective blower

CODE: Five LED flashes
PROBLEM: An abnormal flame proving signal, the flame is likely proved while the gas valve is de-energized
FIX: Check for a leaky gas valve or a gas valve that is stuck open

CODE: Six LED flashes
PROBLEM: Failure to ignite or the flame sensor was lost while running
FIX: Check for: an ungrounded flame sensor; defective hot surface ignitor; control ground continuity; inadequate flame carryover; or rough ignition

CODE: Seven LED flashes
PROBLEM: Limit circuit lockout
FIX: A lockout will occur if the limit or flame rollout is open for longer than 3 minutes. Control will auto-reset after 3 hours.

CODE: Eight LED flashes
PROBLEM: Gas heating lockout, control won’t auto-reset
FIX: Check for a miswired gas valve or a defective control valve

CODE: Ten LED flashes
PROBLEM: Polarity is reversed
FIX: Review instructions to correct polarity

CODE: 1 + 2
PROBLEM: Blower is on after power up
FIX: Occurs if the unit is powered up during a call for heat or opens while the blower is on delay

CODE: 6 + 1
PROBLEM: Ignition lockout
FIX: Control will auto-reset after 3 hours

CODE: LED is off
PROBLEM: Secondary voltage fuse is open
FIX: Check whether the door switch isn’t closed or for a short circuit

CODE: LED is on
PROBLEM: Control circuitry lockout
FIX: Will auto-reset after 1 hour

CODE: LED is solid
PROBLEM: Gas valve relay is stuck while open, flame sense circuit failure, or software-check error
FIX: Reset power to clear the lockout and then replace control if status code repeats itself

heil furnace codes

 


What Our Clients Are Saying About Us

I would recommend KDM for sure

Colin JacobsCourtice, ON

I would recommend KDM for any of the services they provide

Douglas PattersonWhitby, Ontario

KDM was hired for the Installation and relocation of internal gas line

Paul AlisonOshawa, Ontario

Daniel and Steve were amazing, very professional work and courteous

Rajshar MahomesMarkham, Ontario

I would not hesitate to hire Daniel and his crew again

Ian DavidPickering, Ontario

I definitely recommend KDM Home & gas for others

RajeevAjax, Ontario

Everything was quick and efficient

Chris SouthamWhitby, Ontario

He is reliable and pleasant

IreneWhitby, ON

Dan and Steve from KDM did a great job.

RichardAjax, ON

Excellent customer service. Reliable and on time for appointments or called promptly to reschedule.

PaulcathPickering, ON