goodman air conditioner codes

If you’re looking for help fixing your Goodman air conditioner, look no further! Our comprehensive Goodman air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.

CODE: A2.
PROBLEM: Shorted sensor./Open sensor./Sensor disconnected./Sensor out of range.

CODE: A3.
PROBLEM: Shorted sensor./Open sensor./Sensor disconnected./Sensor out of range.

CODE: E5.
PROBLEM: Short in low voltage wiring.

CODE: EE.
PROBLEM: Compressor relay contacts welded.

CODE: b0.
PROBLEM: Indoor blower motor problem./Communications error between indoor and outdoor unit.

CODE: b9.
PROBLEM: Indoor blower motor problem./Blocked filters./Restrictive/ undersized ductwork./Indoor-outdoor unit miss match

CODE: d0.
PROBLEM: Air conditioner/heat pump is wired as part of a communicating system and integrated control module does not contain any shared data.

CODE: d1.
PROBLEM: Air conditioner/heat pump is wired as part of a communicating system and integrated control module contains invalid shared data or network data is invalid for the integrated control module.

CODE: d2.
PROBLEM: Air conditioner/heat pump is wired as part of a communicating system and outdoor unit requires airflow greater than indoor unit’s airflow capability./ Shared data is incompatible with the system or missing parameters.

CODE: d3.
PROBLEM: Shared data sent to integrated control module does not match hardware configuration.

CODE: d4.
PROBLEM: Shared data on memory card has been rejected.

CODE: 01.
PROBLEM: Low refrigerant charge./Restriction in liquid line./Indoor blower motor failure. Indoor thermostat set extremely low.

CODE: 02.
PROBLEM: Blocked condenser coil./Outdoor fan not running.

CODE: 03.
PROBLEM: Intermittent thermostat demand./Faulty compressor relay.

CODE: 04.
PROBLEM: Compressor bearings are seized./Failed compressor run capacitor./Faulty run capacitor wiring./Faulty compressor wiring./Low line voltage.

CODE: 05.
PROBLEM: Power is disconnected./Failed compressor protector./Compressor not properly wired to control.

CODE: 06.
PROBLEM: Compressor start winding is open./Failed compressor run capacitor./Faulty run capacitor wiring./Compressor not properly wired to control./Faulty compressor wiring.

CODE: 07.
PROBLEM: Compressor run winding is open./Compressor no properly wired to control./Faulty compressor wiring.

CODE: 08.
PROBLEM: Low line voltage./ High line voltage.

CODE: 09.
PROBLEM: Control detects secondary voltage less than 18 VAC./Transformer overloaded./Low line voltage.

goodman air conditioner codes

 


What Our Clients Are Saying About Us

Excellent customer service!

TammiWhitby, ON

Very pleasant and gave me full instructions on operation

IreneWhitby, ON

My experience with KDM was spectacular from start to finish.

DwayneToronto, ON

We were very pleased with the work that KDM recently completed for us.

rbm0447Oshawa, ON

Dan and his team were efficient, honest, and easy to deal with

JoeToronto, ON

Amazing service! Great guys, very nice and helpful.

ChauntelleAjax, ON

On the ball, he was organized and efficient.

SteveToronto, ON

Great work with amazing service, the work was done efficiently and precisely.

arachnomme68Courtice, ON

Kdm was professional, knowledgeable, fair priced and very friendly.

Private UserBowmanville, ON

He is courteous, professional, he takes pride in his work.

Randy Whitby, ON