CODE: Green “POWER”
PROBLEM: Module has power
CODE: Red “TRIP”
PROBLEM: Thermostat demand signal. Y1 is present, but the compressor is not running
CODE: Yellow “ALERT” Flash Code 1
PROBLEM: Long Run Time. Compressor is running extremely long run cycles
CODE: Yellow “ALERT” Flash Code 2
PROBLEM: System Pressure Trip. Discharge or suction pressure out of limits or compressor overloaded
CODE: Yellow “ALERT” Flash Code 3
PROBLEM: Short Cycling. Compressor is running only briefly
CODE: Yellow “ALERT” Flash Code 4
PROBLEM: Locked Rotor
CODE: Yellow “ALERT” Flash Code 5
PROBLEM: Open Circuit
CODE: Yellow “ALERT” Flash Code 6
PROBLEM: Open Start Circuit. Current only in run circuit
CODE: Yellow “ALERT” Flash Code 7
PROBLEM: Open Run Circuit. Current only in start circuit
CODE: Yellow “ALERT” Flash Code 8
PROBLEM: Welded Contactor. Compressor always runs
CODE: Yellow “ALERT” Flash Code 9
PROBLEM: Low Voltage. Control circuit < 17VAC